( Brand: Master ), ( Manufacturer Part Number: 72-038-0200 ), ( Type: Hvac Parts Furnace And Heater Parts ), ( Item Length: 3.300 ), ( Item Weight: 0.0400 ), ( Item Width: 2.900 ), ( Country/region Of Manufacture: Cn ), ( Custom Bundle: No ), ( Manufacturer Warranty: 1 Year ), ( Features: Photocell/flame Sensor, For Use With Grainger Item Number 39e998 )
The Masterflex 72038-0200 Photocell Flame Sensor by Honeywell is a versatile and advanced device designed for reliable fire detection applications in various industrial sectors. This photocell flame sensor utilizes optical technology to detect flames, ensuring accurate and quick flame detection, while its robust design ensures longevity and durability in demanding environments.
Design & Construction:The Masterflex 72038-0200 Photocell Flame Sensor features a compact, rugged housing that provides protects against harsh conditions. Its fiber optic material is highly resistant to UV and IR radiation, making it ideal for use in areas with high ambient light or challenging environmental conditions. This sensor is designed for easy installation, featuring a threaded socket for direct sensor mounting.
Technical Capabilities:The Masterflex 72038-0200 Photocell Flame Sensor employs a photocell element with a high sensitivity, permitting it to detect small flames, while its fast response time ensures quick detection of developing fires. This photocell flame sensor operates on a selectable current of 100mA or 500mA, and its wide temperature range of -40 C to 85 C ensures versatile usage across various applications.
Applications:The Masterflex 72038-0200 Photocell Flame Sensor is extensively used in industries such as oil and gas, petrochemical, power generation, and wastewater treatment, where reliable fire detection is crucial for safety and operational efficiency. Given its unique features, this sensor is an excellent choice for applications in refineries, pipelines, power plants, and other industrial facilities where fire hazards may pose a significant risk.
Installation & Calibration:Installation of the Masterflex 72038-0200 Photocell Flame Sensor is a straightforward process, requiring only a few simple steps. The sensor can be installed directly onto a flameproof junction box, utilizing its threaded socket. It features a factory-calibrated relation between flame detection and dry contact signal output, ensuring consistent performance and simplicity in the field. However, periodic calibration is recommended to maintain optimal sensor performance.
Maintenance & Troubleshooting:Regular maintenance of the Masterflex 72038-0200 Photocell Flame Sensor involves cleaning the sensor element to ensure no contaminants obstruct the sensing window. Ensure the signal output is checked regularly for open or short circuits, and perform periodic calibrations as recommended by Honeywell or industry standards. In case of issues, consult the user manual or contact Honeywell's customer support for troubleshooting assistance.
Conclusion:The Masterflex 72038-0200 Photocell Flame Sensor by Honeywell is a top-of-the-line, robust, and versatile optical flame detection device, widely applied in various industries to minimize fire risks and optimize operations. With its sensitive photocell element, fast response time, durable construction, and straightforward installation process, this sensor offers a comprehensive fire detection solution for a safer and more efficient industrial environment.
The Master 72-038-0200 Photocell Flame Sensor is a popular choice in various industries for flame detection applications. Like any other technology, it comes with its advantages and disadvantages. Here is an unbiased analysis to help you make an informed decision about whether to buy this photocell flame sensor.
Pros:1. High sensitivity: The Master 72-038-0200 photocell flame sensor is known for its high sensitivity to flames, making it an excellent choice for applications where quick detection is crucial.
2. Compact design: The sensor is compact and lightweight, making it easy to install in various applications and systems.
3. Wide detection range: The photocell flame sensor's wide detection range enables it to detect flames from various angles and at different distances, offering greater flexibility in installation.
4. Simple installation: The sensor is simple to install as it does not require any external power supply, making the setup process hassle-free.
Cons:1. Dependence on external light source: The photocell element in the sensor relies on an external light source for operation, which means its effectiveness may be affected when used in low-light conditions or in environments with intense light.
2. No specific temperature measurement: The Master 72-038-0200 photocell flame sensor does not provide a temperature measurement, making it unsuitable for applications requiring temperature monitoring.
3. Fragile glass envelope: The sensor's glass envelope is somewhat fragile and can be easily damaged during installation or regular usage, requiring careful handling and maintenance.
4. May require additional components: While the sensor itself is simple and does not require external power, certain applications may require additional components like a relay or transistor for proper integration into the system, adding to the overall cost.
Conclusion:The Master 72-038-0200 Photocell Flame Sensor offers an excellent balance of sensitivity and ease of use. Its high sensitivity and wide detection range make it a valuable asset for applications where quick flame detection is essential. However, it may not be suitable for applications requiring temperature measurement or when used in environments with poor lighting conditions. Despite its fragile glass envelope, this sensor's compact design, simple installation process, and versatility make it a popular choice for various industries.
Recommendation:If you are looking for a reliable and sensitive photocell flame sensor for applications where quick flame detection and a simple installation process are crucial, the Master 72-038-0200 Photocell Flame Sensor is a solid choice. However, be sure to consider other factors, such as temperature requirements and the presence of external light sources, before making your decision. You may want to discuss your specific application with a technical expert to determine if this sensor is the best fit for your needs.
MASTER 72-038-0200 Photocell/Flame Sensor: Sensor, For Use With Grainger Number 39E998, Mfr. Electrical Outlet's. Model Number MH-70-SS-A, Fits Brand Master, Pro temp, Remington Details
Light Industrial. Electrical Boxes. And Enclosures.